  1. DTC3180/3280A SCSI HOST ADAPTER
  2. MAY 25,1990,REVISION A
  3. SWITCH SETTINGS & SETUP
  4. -----------------------------------------------------------------------------
  5. JUMPER &                                                            INSTALLED
  6. SWITCH #    FUNTION                        DEFAULT                       Y/N
  7.                                                                   OPEN/CLOSED
  8. -----------------------------------------------------------------------------
  9. W1 (123)    MEMORY CONFIGURATION JUMPER    2K STATIC RAM          2-3
  10.  
  11. W2 (123)    FLOPPY PORT ADDRESS JUMPER     PRIMARY PORT ADDRESS   1-2
  12.  
  13. SW1 (1-4)   INTERRUPT "B" SWITCHES         DISABLED               OPEN
  14.  
  15. SW1 (5-6)   MEMORY ADDRESS SWITCHES        D800H                  OPEN
  16.  
  17. SW1 (7)     DUAL SPEED SWITCH              DUAL SPEED DISABLED    OPEN
  18.  
  19. SW1 (8)     PIN 2 POLARITY SWITCH          AT-TYPE FLOPPY DRIVE   CLOSED
  20.  
  21. SW1 (9)     FLOPPY PRECOMPENSATION         DATA RATE DEPENDENT    OPEN
  22.  
  23. SW1 (10)    FLOPPY ENABLE SWITCH           FLOPPY ENABLED         CLOSED
  24.  
  25. SW1 (1-2)   INTERRUPT "A" SWITCHES         DISABLED               OPEN
  26.  
  27. SW1 (3-4)   FACTORY SET                    ----                   OPEN
  28.  
  29. SW1 (5)     SCSI PARITY SWITCH             PARITY ENABLED         OPEN
  30.  
  31. SW1 (6-8)   SCSI ID                        SCSI ID IS 7           OPEN
  32. -----------------------------------------------------------------------------
  33. MEMORY CONFIGURATION JUMPER - W1
  34. Used to configure the DTC 31/3280 for a 2K or an 8K static ram chip.
  35.  
  36. FLOPPY PORT ADDRESS JUMPER - W2
  37. Controls primary & secondary port addresses for the hard and floppy drives.
  38.  
  39. INTERRUPT "B" SWITCHES - SW1 (1-4)
  40. Defines interrupt level reported to the computer during an Inquiry command.
  41. Interrupt "B" must specify the same interrupt level as defined by the
  42. interrupt "A" switches.
  43.             -------------------------------------------
  44.            |       SWITCHES                | INTERRUPT |
  45.            |-------------------------------------------|
  46.            |   1   |   2   |   3   |   4   |           |
  47.            |-------------------------------------------|
  48.            | OPEN  | OPEN  | OPEN  | OPEN  | DISABLED  |
  49.            |-------------------------------------------|
  50.            | CLOSED| OPEN  | OPEN  | OPEN  |    15     |
  51.            |-------------------------------------------|
  52.            | OPEN  | CLOSED| OPEN  | OPEN  |    12     |
  53.            |-------------------------------------------|
  54.            | OPEN  | OPEN  | CLOSED| OPEN  |    11*    |
  55.            |-------------------------------------------|
  56.            | OPEN  | OPEN  | OPEN  | CLOSED|    10     |
  57.             -------------------------------------------
  58.  
  59.  
  60. MEMORY ADDRESS SWITCHES - SW1 (5-6)
  61. THE DTC 31/3280 requires a 16K memory space.  The memory address switches
  62. define the base, or starting address of this memory space.
  63.  
  64.             SWITCHES   | BASE ADDRESS
  65.            ----|-------|-------------
  66.            ON  | ON    | CC00H              OPEN = OFF
  67.            OFF | ON    | C800H            CLOSED = ON
  68.            ON  | OFF   | DC00H
  69.           *OFF | OFF   | D800H
  70.  
  71.  
  72. DUAL SPEED SWITCH - SW1 (7)
  73. The Dual Speed Switch allows the DTC3280 to support dual speed floppy disk
  74. drives.  This switch must be closed when connecting dual speed floppy disk
  75. drives to the DTC3280.  The default setting for this switch is open.
  76.  
  77.  SW1 (7) *Open - Dual speed floppy disk drives not supported
  78.  SW1 (7) Closed - Dual speed floppy disk drives supported
  79.  
  80. Pin 2 Polarity Switch - SW1 (8)
  81. The Pin 2 Polarity Switch allows the DTC3280 to support AT and PS/2-type
  82. floppy disk drives.
  83.  
  84.     DRIVE TYPE         SWITCH SETTING         DRIVE SELECT
  85.        AT                 CLOSED                   2
  86.       PS/2                 OPEN                    2
  87.     AT & PS/2              OPEN                 1,3 or 4
  88.  
  89. FLOPPY PRECOMPENSATION CONTROL SWITCH - SW1 (9)
  90. The floppy precompensation control switch is used to control the amount
  91. of precompensation.
  92.  
  93.   SW1 (9) CLOSED:  Fixed at 125ns
  94.   SW1 (9) *OPEN:   Data-Rate-Dependent
  95.  
  96. FLOPPY ENABLE SWITCH - SW1 (10)
  97. The floppy circuitry on the DTC3280 is enabled when this switch is closed.
  98.  
  99.   SW1 (10) *CLOSED:  Floppy circuitry enabled
  100.   SW1 (10) OPEN:     Floppy circuitry disabled
  101.  
  102. INTERRUPT "A" SWITCHES - SW2 (1-2)
  103. The Interrupt "A" switches define the DTC31/3280 interrupt level.  The
  104. Host Adaptor can be configured to use interrupt level 10,11,12, or 13.
  105. The table below defines the switch settings and the corresponding
  106. interrupt level.
  107. Note:  The DTC31/3280 does not use interrupts in a DOS enviroment.
  108.      SWITCHES       INTERRUPT
  109.       1  |  2       LEVEL
  110.      ----|--------------------
  111.      OFF | OFF       15           OPEN = OFF
  112.       ON | OFF       12         CLOSED = ON
  113.      OFF | ON        11
  114.       ON | ON        10
  115.  
  116. SW2 (3-4)
  117. Reserved.  For factory use only must be open to operate properly.
  118.  
  119. SCSI PARITY SWITCH - SW2 (5)
  120. The SCSI parity switch enables the parity bit on the SCSI bus.
  121.  
  122.   SW2 (5) CLOSED - Parity disabled
  123.   SW2 (5) OPEN   - Parity enabled
  124.  
  125. SCSI ID SWITCHES - SW2 (6-8)
  126. Each device on the SCSI bus, including the DTC31/3280, must have a
  127. unique SCSI ID from zero to seven.  These switches are used to define
  128. the SCSI ID for the DTC31/3280, as described below.
  129.  
  130.      SWITCH |  0   1   2   3   4   5   6   7
  131.      -------|--------------------------------
  132.         6   | ON  OFF ON  OFF ON  OFF ON  OFF
  133.         7   | ON  ON  OFF ON  OFF ON  OFF OFF
  134.         8   | ON  ON  ON  ON  OFF OFF OFF OFF
  135.  
  136.  
  137. DETERMINE YOUR SOFTWARE REQUIREMENTS
  138. The DTC31/3280 software contains drivers and utilities that, in conjunction
  139. with the DTC31/3280 hardware, allow you to install and operate multiple
  140. SCSI devices.  This section should be referred to in order to determine
  141. the software requirements for your particular configuration.  The files
  142. contained in the DTC31/3280 software diskette are as follows:
  143.  
  144.   GSCSI4.SYS           DTC31/3280 DOS Driver
  145.   GSCSI4.EXE           DTC31/3280 Removable Cartridge Driver
  146.   GFDISK.EXE           Format and partition utility
  147.   GSDIAG.EXE           Low-level format utility
  148.   AUTOEXEC.BAT         Auto-executable file
  149.   CONFIG.SYS           System configuration file
  150.  
  151. GSCSI4.SYS is a DOS device driver that is required if your system has more
  152. than two SCSI devices or if your system has any ST506 (MFM,RLL) or ESDI
  153. hard disk drives.
  154.  
  155. GSCSI4.EXE is a DOS device driver that supports SCSI removable cartridge
  156. drivers.  If you are connecting a removable cartridge SCSI device to the
  157. DTC31/3280, you need to install GSCSI4.EXE.
  158.  
  159. INSTALL THE DTC31/3280
  160. The following steps are required to install the DTC31/3280 in your computer:
  161.  
  162.  * Set the ID of each SCSI device on your system.  Each SCSI device, including
  163.    the DTC31/3280, must have a unique ID from zero to seven.
  164.  
  165.  * Install internal SCSI devices into the computer.
  166.  
  167.  * NOTE:  The first and the last devices connected to the SCSI bus must have
  168.    terminating resistors.  If the DTC31/3280 is not physically the first or
  169.    last device on the cable, remove the TP1 and TP2 resistor packs.  The
  170.    DTC31/3280 comes from the factory to be either the first or the last device.
  171.  
  172.  * If you are using internal SCSI devices, connect one end of the 50 pin header
  173.    on the DTC31/3280.
  174.  
  175.  * Remove one of the metal brackets from any empty expansion slot in the rear
  176.    of the computer chassis and insert the DTC31/3280.
  177.  
  178.  * Connect the internal SCSI devices to the 50 pin ribbon cable.  Be sure
  179.    that pin 1 of the 50 pin header is connected to pin 1 of the SCSI devices.
  180.  
  181.  * Reassemble the computer.  Refer to your computer manual for the proper
  182.    procedure.
  183.  
  184.  * Connect any external SCSI devices to the external connector on the
  185.    DTC31/3280 using the 50-pin shielded cable.
  186.  
  187. DETERMINE YOUR SOFTWARE REQUIREMENTS
  188. The DTC31/3280 software contains drivers and utilities that, in conjunction
  189. with the DTC31/3280 hardware, allow you to install and operate multiple
  190. SCSI devices.  This section should be referred to in order to determine the
  191. software requirements for your particular configuration.  The files contained
  192. on the DTC31/3280 software diskette are as follows:
  193.  
  194.  GSCSI4.SYS           DTC31/3280 DOS DRIVER
  195.  GSCSI4.EXE           DTC31/3280 REMOVEABLE CARTRIDGE DRIVER
  196.  GSFDISK.EXE          PARTITION UTILITY
  197.  GSDIAG.EXE           LOW-LEVEL FORMAT UTILITY
  198.  AUTOEXEC.BAT         AUTO-EXECUTABLE FILE
  199.  CONFIG.SYS           SYSTEM CONFIGURATION FILE
  200.  
  201. GSCSI4.SYS is a DOS device driver that is required if your system has more
  202. than two SCSI devices or if your system has any ST506 (MFM,RLL) or ESDI
  203. hard disk drives.
  204.  
  205. GSCSI4.EXE is a DOS device driver that supports SCSI removeable cartridge
  206. drives.  If you are connecting a removeable cartridge SCSI device to the
  207. DTC31/3280, you need to install GSCSI4.EXE.
  208.  
  209. INSTALLING THE DTC31/3280 SOFTWARE ON A HARD DISK (NON-BOOTABLE CONFIG.)
  210. Follow the procedure below to install the DTC31/3280 software on your hard
  211. disk drive. where Drive C: represents a hard disk drive and drive A:
  212. represents a floppy disk drive.
  213.  
  214. * Insert the DTC31/3280 software diskette in drive A:.  At the DOS prompt,
  215.   enter the following command to change to the root directory:
  216.  
  217.                            CD C:\
  218.  
  219. * At the new DOS prompt, enter the following command to copy the files
  220.   to the hard disk:
  221.  
  222.                            Copy A:G*.* C:
  223.  
  224. * If your system configuration does not require the DTC31/3280 DOS drivers,
  225.   GSCSI4.EXE and GSCSI4.SYS your software installation is now complete.
  226.  
  227. * If your system configuration requires GSCSI4.SYS, add the following
  228.   statement to your CONFIG.SYS file:
  229.  
  230.                            DEVICE=C:GSCSI4.SYS
  231.  
  232.  If your system configuration requires GSCSI4.SYS, add the following
  233.  statement to your CONFIG.SYS file:
  234.  
  235.                            COPY A:CONFIG.SYS C:
  236.  
  237. * If your system configuration requires GSCSI4.EXE, add the following
  238.   statement to your AUTOEXEC.BAT file:
  239.  
  240.                            GSCSI4
  241.  
  242.  If your system does not have an AUTOEXEC.BAT file, copy this file from
  243.  the DTC31/3280 software diskette to your hard disk by entering the
  244.  following command:
  245.  
  246.                            COPY A:AUTOEXEC.BAT C:
  247.  
  248. * Your software installation is now complete.  Please note, you must re-boot
  249.   your computer prior to accessing any of the SCSI devices.
  250.  
  251. INSTALLING THE DTC31/3280 SOFTWARE ON A DUAL-FLOPPY SYSTEM (BOOTABLE CONFIG.)
  252. If your system does not have a hard disk drive but has two floppy disk drives,
  253. follow the procedure below to install the DTC31/3280 software on your start-
  254. up diskette.  In the procedure, both drive A: and B: represent floppy disk
  255. drives.
  256.  
  257. * Switch on your system with the start-up diskette in drive A:.  Insert the
  258.   DTC31/3280 software diskette in Drive B:.  Enter the following command
  259.   to change the root directory:
  260.  
  261.                            CD A:\
  262.  
  263. * Copy the files from the DTC31/3280 software diskette to your start-up
  264.   diskette with the following command:
  265.  
  266.                            Copy B:G*.* A:
  267.  
  268. * If your system configuration does not require the DTC31/3280 DOS drivers,
  269.   GSCSI4.EXE and GSCSI4.SYS, your software installation is now complete.
  270.  
  271. * If your system configuration requires GSCSI.SYS, add the following state-
  272.   ment to your CONFIG.SYS file:
  273.  
  274.                            DEVICE=A:GSCSI4.SYS
  275.  
  276.   If your system does not have a CONFIG.SYS file, copy this file from the
  277.   DTC31/3280 software diskette to your start-up diskette by entering the
  278.   following command:
  279.  
  280.                            Copy B:CONFIG.SYS A:
  281.  
  282. * If your system configuration requires GSCSI4.EXE, add the following state-
  283.   ment to your AUTOEXEC.BAT file:
  284.  
  285.                            GSCSI4
  286.  
  287.   If your system does not have an AUTOEXEC.BAT file, copy this file from
  288.   the DTC31/3280 software diskette to your start-up diskette by entering the
  289.   following command:
  290.  
  291.                            COPY B:AUTOEXEC.BAT A:
  292.  
  293. * Your software installation is now complete.  Please note, you must re-boot
  294.   your computer prior to accessing any of the SCSI devices.
  295.  
  296. USING GSDIAG
  297. The DTC31/3280 software includes GSDIAG low-level format utility for SCSI
  298. disk drives.  Follow the procedure below to invoke this utility.
  299.  
  300. * At the DOS prompt, enter the following command:
  301.  
  302.                            GSDIAG
  303.  
  304. * Follow the instructions on your computer screen.  Select Option 1 to
  305.   format with the Drive Default Values.  This option uses the parameters
  306.   defined by the SCSI disk drive.  If your system has a special configuration,
  307.   it may be necessary to select Format Options 2-4 instead of selecting the
  308.   default values.  Option 2 allows you to manually enter a defect map.
  309.   Options 3 and 4 are used to change the Mode Select parameters.
  310.  
  311. GSFDISK
  312. GSFDISK is the DTC SCSI host adapter partition utility.  This utility can be
  313. used to create a single or multiple partition on a SCSI drive.  DOS version
  314. 4.0 or greater must be used to create a single or multiple partition on a
  315. SCSI drive.  DOS version 4.0 or greater must be used to create a partition
  316. greater than 32 MB (which is a DOS limitation).
  317.  
  318.                            NOTE
  319.  This procedure must be repeated for all the SCSI disk drives.  After part-
  320.  itioning each SCSI disk drive, the system will reboot.
  321.  
  322. Use the following steps to partition the SCSI disk drive.  At the DOS prompt:
  323.               Type the following:
  324.                            GSFDISK
  325.  
  326. Follow the on-screen message to complete the set-up partition procedure.
  327.  